Product · Technology
HS-Korea Co., Ltd. is a total environmental service company that realizes a clean and clear world.
Water quality measuring equipment
HACA-4000
Online COD Analyzer
The permanganate (Mn) COD continuous automatic analyzer, HACA-4000, automates the acidic potassium permanganate method for water quality testing.
It determines COD by measuring the permanganate consumed during oxidation, with the titration endpoint identified by an increase in ORP.
Featuring patented technology and pre-measurement logic for enhanced performance, the HACA-4000 is optimized for water quality TMS applications in compliance with the latest communication standards.
-
Approval on model : No. WTMS-COD-2017-7
-
혁신제품인증(제2021-182호)
-
GS인증 (21-0239)
Request for
technical data
technical data
Product/Technical Inquiry
Request for quotation
Product Features
Product specifications
Product Features

Compliant with the latest revised water quality TMS communication standards

Pre-measurement logic applied to enhance measurement accuracy

Proprietary multi-channel valve applied for precise dosing of samples and reagents

Built-in user-centric operating program with enhanced security features

Built-in various features to enhance user convenience

Building a diverse product lineup with sophisticated designs
Product specifications
| Measurement item | Chemical Oxygen Demand |
| Measurement method | Chemical oxidation method (acidic condition, potassium permanganate-based decomposition) |
| Measurement range | 0~200mg/L (adjustable within full scale, F.S.) |
| Measurement interval | 60 min (adjustable) |
| Detection limit | ≤ 0.6 mg/L F.S. |
| Accuracy | ±2% F.S. |
| Reproducibility | ±2% F.S. |
| Linearity | ±4% F.S. |
| Zero/Span Drift | ±2% F.S. |
| Heating method | Oil heating using a heater |
| Sample/Reagent measurement method | Stepper motor pulse control system |
| Sample/Reagent distribution method | 6-port distribution control method (multi-channel valve system for quantitative injection) |
| OS | Windows 7 (CPU) |
| 출력 | DC 4~20ma, RS-232C (Korea Environment Corporation Standard / On-site Self-Management Use) |
| Status indicator | Equipment normal, calibration in progress, malfunction |
| Indicator | Color TFT LED 10.4″ (touchscreen) |
| Power | AC 220V, 50/60Hz |
| Power consumption | Avg 150W (Max 450W) |
| Data storage capacity | HDD 100G or more |
| Data output method | USB terminal adoption |
| Enclosure / Size | Steel 1.5T / 645(W) × 493(D) × 1600(H) mm |